Il Pylon-Monitor può leggere due stack da 7 batterie Pylontech Force L1, cella per cella?
Kan de Pylon-Monitor twee stacks van 7 Pylontech Force L1-batterijen uitlezen, cel per cel?
Chiesta il ·Aggiornata ·1 risposta
In breve
Sì. La Force L1 è supportata e ogni batteria e ogni cella viene mostrata singolarmente. Un Pylon-Monitor sul master legge fino a 16 batterie; se ogni stack ha il proprio master, serve un Pylon-Monitor per stack.
S
Cliente S.Domanda
Italiano · traduzione
Vorrei acquistare un Pylon-Monitor ma avrei bisogno di qualche informazione in più. Ho 2 stack da 7 batterie Pylontech Force L1 (2 × 7 pacchi: 3,55 kWh × 14), master e slave. Posso leggere entrambi gli stack cella per cella con questo monitor?
🇬🇧 Inglese · Traduzione inglese a cura del nostro team
I would like to buy a Pylon-Monitor but would like some more information. I have 2 stacks of 7 Pylontech Force L1 batteries (2 × 7 packs: 3.55 kWh × 14), master and slave. Can I read both stacks cell by cell with this monitor?
Originale · Nederlands
Ik had graag een Pylon-Monitor aangekocht, maar had wat meer informatie gewenst. Ik heb 2 stacks van 7 Pylontech Force L1-batterijen (2 × 7 packs: 3,55 kWh × 14), master en slave. Kan ik met deze monitor beide stacks cel per cel uitlezen?
PM
Team Pylon-MonitorRisposta ufficiale
Italiano · traduzione
Grazie per l’interesse. Sì, la Pylontech Force L1 è supportata e il Pylon-Monitor mostra ogni batteria e ogni cella singolarmente: le 15 tensioni di cella di ogni modulo, più carica, stato di salute, cicli e temperature.
Quante unità servono dipende da come sono cablati i due stack:
- Se i due stack sono collegati in un unico sistema con un solo master (lo stack slave collegato al master tramite le porte link), un Pylon-Monitor sulla porta Console del master legge tutte e 14 le batterie — ne gestisce fino a 16.
- Se ogni stack ha il proprio master, serve un Pylon-Monitor per stack, ciascuno collegato al master del proprio stack.
Se non siete sicuri, inviateci una foto del cablaggio tra i due stack e vi diremo.
🇬🇧 Inglese
Thank you for your interest. Yes, the Pylontech Force L1 is supported, and the Pylon-Monitor shows every battery and every cell individually: each module’s 15 cell voltages, plus its charge, health, cycles and temperatures.
How many units you need depends on how your two stacks are wired:
- If the two stacks are linked into one system with a single master (the slave stack connected to the master through the link ports), one Pylon-Monitor on the master’s Console port reads all 14 batteries — it handles up to 16.
- If each stack has its own master, you need one Pylon-Monitor per stack, each plugged into that stack’s master.
If you are not sure, send us a photo of the cabling between the two stacks and we will tell you.
Originale · Nederlands
Bedankt voor uw interesse. Ja, de Pylontech Force L1 wordt ondersteund en de Pylon-Monitor toont elke batterij en elke cel afzonderlijk: per module de 15 celspanningen, plus lading, gezondheid, cycli en temperaturen.
Hoeveel apparaten u nodig heeft, hangt af van hoe uw twee stacks zijn aangesloten:
- Zijn de twee stacks tot één systeem met één master gekoppeld (de slave-stack via de linkpoorten aan de master), dan leest één Pylon-Monitor op de Console-poort van de master alle 14 batterijen uit — tot 16 worden ondersteund.
- Heeft elke stack een eigen master, dan heeft u één Pylon-Monitor per stack nodig, elk op de master van die stack.
Weet u het niet zeker, stuur ons dan een foto van de bekabeling tussen de twee stacks en wij laten u weten hoe het zit.