On the raw data page, the "bat" reply stops in the middle of cell 12. Is something wrong?

Asked · Updated · 2 answers

Short answer

Fixed in firmware v3.6.0, Lite v1.3.0, V3 v1.2.0 and V3 Lite v1.2.0 (generation 1: v3.1.3): long replies on the raw data page are no longer cut in the middle without notice. Only that diagnostic page was affected: the dashboard, the JSON API and MQTT always received the complete data.

Customer J. 🇩🇪 Germany Question

I am really excited about your product, it works very well. There is probably a small bug I would like to report: in the raw battery data view, the bat response is truncated in the middle of cell 12.

Pylon-Monitor teamOfficial answer

Thank you for this precise report. You are right: to save memory, the raw data page only keeps a limited copy of each battery reply, and with 15 cells the "bat" table (and the "pwr" table beyond 11 lines) is cut without any notice.

Only this diagnostic page is affected: the dashboard, the JSON API and MQTT always receive the complete data. This will be fixed in a coming firmware version.

UpdatePylon-Monitor team

Firmware v3.6.0, Lite v1.3.0, V3 v1.2.0 and V3 Lite v1.2.0 (generation 1: v3.1.3) (27 November 2026): the raw data page no longer cuts long replies in the middle without notice.

Was this answer helpful?
#raw data#bat#15 cells#diagnostics#firmware

Published without names or contact details. Customers are shown by initial and country only.

Join 6,000 Pylon-Monitor fans on Facebook

News, firmware updates, real installations and tips: follow the page and put your questions to the community.