With only one battery over the winter, Home Assistant keeps "Battery 1" to "Battery 5" entities that stay "unknown"

Asked · Updated · 2 answers

Short answer

Fixed in firmware v3.6.0, Lite v1.3.0, V3 v1.2.0 and V3 Lite v1.2.0 (generation 1: v3.1.3): the device now removes the Home Assistant sensors of batteries that are no longer in the stack, automatically, once the battery count is stable. With a single battery, the main sensors keep receiving its values, as before.

Customer C. 🇩🇪 Germany Question

Over the winter I run only one battery unit. Since then the monitor no longer publishes pylon-monitor/battery1/state, only pylon-monitor/state. However, the MQTT discovery still announces the sensors b1_* to b5_*, so Home Assistant creates the entities but they never receive values ("unknown"). Expected: discovery should only announce the units that are present. Individual cell voltages per unit over MQTT would also be great.

Pylon-Monitor teamOfficial answer

Thank you for this precise report, you are right. With a single battery, the per-battery sensors are deliberately not published, because they would be identical to the main sensors (sensor.pylon_monitor_battery_soc, _battery_voltage, _charge_cycles, _battery_soh, _battery_state), which keep receiving the values of your battery.

The fault is that the device does not remove the per-battery sensors it announced earlier, when you had more units, so Home Assistant keeps them as "unknown". Until this is fixed, simply delete these "Battery 1" to "Battery 5" entities in Home Assistant, or clear their retained discovery topics (homeassistant/sensor/<device name>/b1_soc/config, and so on) with an empty retained message. They are announced again automatically as soon as more batteries are connected.

Removing the stale sensors is planned for the coming firmware version; per-battery cell voltages over MQTT are noted as a suggestion.

UpdatePylon-Monitor team

Firmware v3.6.0, Lite v1.3.0, V3 v1.2.0 and V3 Lite v1.2.0 (generation 1: v3.1.3) (27 November 2026): the sensors of batteries that are no longer in the stack are now removed from Home Assistant automatically, once the battery count is stable. Per-battery cell voltages over MQTT remain noted as a suggestion.