Designed & made in France 6K fans on Facebook · Follow us
New: firmware 3.6 — your Pylon-Monitor now speaks your language, with a brand-new screen. Free update. See what's new →
Answered Readings & data All models IT + EN

My old US2000 shows low health and disconnects when the batteries discharge. Should I replace it with a US2000C?

La mia vecchia US2000 ha una salute bassa e si scollega quando le batterie si scaricano. Devo sostituirla con una US2000C?

Asked · Updated · 1 answer

Short answer

Yes. This is typical of an aged battery: with low health, one of its cells reaches the minimum voltage first during discharge, its BMS disconnects it for protection and the master shows an error. Switching it back on does not help, and a BMS update cannot restore lost cell capacity. Replacing it makes the stack stable.

Customer R. 🇮🇹 Italy Question
🇬🇧 English · English translation by our team

I added a US2000C in excellent shape, as the monitor shows (number 5). Number 6 is an old US2000; it shows a low health percentage, with errors. When there is no sun and they all discharge, number 6 disconnects and the error light comes on at the master; if I switch it back on the error goes away, then it disconnects again. Do you recommend replacing the US2000 with a US2000C? Or is there an update for the batteries?

Original · Italiano

Ho aggiunto una US2000C in ottima forma, come si vede dal monitor (la numero 5). La numero 6 è una vecchia US2000 e mi dà una percentuale di vita bassa, con errori. Quando non c'è sole e si scaricano tutte, la numero 6 si scollega e sul master si accende l'errore; se la riaccendo l'errore sparisce, per poi scollegarsi di nuovo. Mi consigliate di togliere la US2000 e mettere una US2000C? Oppure c'è un aggiornamento per le batterie?

Pylon-Monitor teamOfficial answer
🇬🇧 English

What you describe is typical of an aged battery: with low health, one of its cells reaches the minimum voltage first during discharge, its BMS disconnects it for protection and the master reports the error. Switching it back on does not solve it, because it happens again at the next discharge.

Yes, we recommend replacing the old US2000 with the US2000C: that is what makes the stack stable. A BMS update does not give back the capacity a cell has lost. Before connecting it, switch the US2000C on alone and check that its ALM LED stays off.

Original · Italiano

Quello che descrive è tipico di una batteria invecchiata: con una salute bassa, durante la scarica una delle sue celle arriva per prima alla tensione minima, il suo BMS la scollega per protezione e il master segnala l'errore. Riaccenderla non risolve, perché alla scarica successiva succede di nuovo.

Sì, Le consigliamo di sostituire la vecchia US2000 con la US2000C: è la soluzione che rende il pacco stabile. Un aggiornamento del BMS non restituisce la capacità persa da una cella. Prima di collegarla, accenda la US2000C da sola e verifichi che il LED ALM resti spento.

Was this answer helpful?
#US2000#US2000C#SOH#disconnects#replace a battery

Published without names or contact details. Customers are shown by initial and country only.

Join 6,000 Pylon-Monitor fans on Facebook

News, firmware updates, real installations and tips: follow the page and put your questions to the community.

Follow us on Facebook