In my 4× US3000C, one battery always shows 30 % more charge than the others, even after guided balancing
Nel mio pacco di 4 US3000C una batteria ha sempre il 30 % di carica in più delle altre, anche dopo il bilanciamento guidato
Asked ·Updated ·1 answer
Short answer
The battery with the highest SOC was actually the best balanced. Batteries 1 and 2 each had one lagging cell that drops first during discharge, so their BMS lowers their SOC. The Pylontech BMS balances only at the top of charge, slowly: let the system reach 100 % and stay there a few hours, several days in a row, and watch the cell spread at full charge. Still above about 100 mV after one or two weeks: the cell is probably weak (Pylontech warranty via the seller).
G
Customer G.🇮🇹 ItalyQuestion
🇬🇧 English · English translation by our team
For about a week I have been monitoring my pack of 4 US3000C batteries, very happy with the cloud dashboard. The monitoring showed that one battery always has 30 % more charge than the other 3. I also tried the guided balancing procedure, but the difference remained. Any suggestion on how to proceed?
Original · Italiano
Da circa una settimana sto tenendo sotto controllo il mio pacco di 4 batterie US3000C, molto contento della dashboard via Cloud. Il monitoraggio mi ha mostrato che ho sempre una batteria con una carica del 30 % superiore alle altre 3, e ho provato anche la procedura del bilanciamento guidato, ma tale differenza è rimasta. Avete qualche suggerimento su come potrei procedere?
PM
Pylon-Monitor teamOfficial answer
🇬🇧 English
We looked at your installation's data: it is actually not battery 4 that has too much charge. Batteries 1 and 2 each have one cell that lags behind (cell 12 of battery 1, cell 2 of battery 2): during discharge these cells drop first and the BMS lowers the SOC of those batteries. All four are at the same voltage, so the SOC difference comes from there, while battery 4 is the best balanced.
The Pylontech BMS balances cells only at the top of charge, and very slowly. With such a large gap, a single two-hour session is not enough: let the system reach 100 % and stay there a few hours, several days in a row, and follow the cell spread of batteries 1 and 2 at full charge on the dashboard.
If after one or two weeks the spread at full charge stays above about 100 mV on one of these batteries, the cell is probably weak: in that case, contact the seller for the Pylontech warranty.
Original · Italiano
Abbiamo guardato i dati del Suo impianto: in realtà non è la batteria 4 ad avere troppa carica. Le batterie 1 e 2 hanno ciascuna una cella che resta indietro (la cella 12 della batteria 1, la cella 2 della batteria 2): durante la scarica queste celle scendono per prime e il BMS abbassa il SOC di quelle batterie. Tutte e quattro sono alla stessa tensione, quindi la differenza di SOC viene da lì, mentre la batteria 4 è la più equilibrata.
Il BMS Pylontech bilancia le celle solo in cima alla carica e molto lentamente. Con uno scarto così grande, una sola sessione di due ore non basta: lasci arrivare l'impianto al 100 % e restarci alcune ore, per diversi giorni di seguito, e segua sulla dashboard lo scarto delle celle delle batterie 1 e 2 a carica completa.
Se dopo una o due settimane lo scarto a carica completa resta sopra circa 100 mV su una di queste batterie, la cella è probabilmente debole: in quel caso conviene rivolgersi al venditore per la garanzia Pylontech.