On my 8-battery mixed stack some batteries show the wrong model, serial number and cycle count
Op mijn gemengde stack van 8 batterijen tonen sommige batterijen een verkeerd model, serienummer en aantal cycli
Asked ·Updated ·1 answer
Short answer
On large mixed stacks (here 4 × US5000C + 4 × US3000C) a battery’s answer could arrive late and be attributed to the wrong battery. Fixed in firmware v3.4.1 (3 October 2026): every answer is now checked against the battery it came from, and model, serial number and cycles correct themselves within a few minutes of updating.
J
Customer J.Question
🇬🇧 English · English translation by our team
The communication between my 8 batteries is not good: 4× US5000C and 4× US3000C. In my dashboard I don’t see the right information.
Original · Nederlands
De communicatie tussen mijn 8 accu’s is niet goed: 4× US5000C en 4× US3000C. In mijn dashboard zie ik niet de juiste informatie.
PM
Pylon-Monitor teamOfficial answer
🇬🇧 English
Thank you for the details — we could see the problem directly in your Cloud data. On your 8-battery stack (4 × US5000C + 4 × US3000C), some batteries show no model or serial number and the wrong cycle count, while your 6-battery stack reads fine. On large mixed stacks, a battery’s answer sometimes arrived late and was attributed to the wrong battery.
This is fixed in firmware v3.4.1, released on 3 October 2026. Please update via “Update firmware”: every answer is now checked against the battery it came from, and the model, serial number and cycles of each battery correct themselves within a couple of minutes. If anything still looks wrong after the update, just reply to this email.
Original · Nederlands
Bedankt voor de details — we zagen het probleem direct in uw Cloud-gegevens. Bij uw stack van 8 batterijen (4 × US5000C + 4 × US3000C) tonen sommige batterijen geen model of serienummer en een verkeerd aantal cycli, terwijl uw stack van 6 batterijen goed wordt uitgelezen. Bij grote gemengde stacks kwam het antwoord van een batterij soms te laat aan en werd het aan de verkeerde batterij toegewezen.
Dit is verholpen in firmware v3.4.1, uitgebracht op 3 oktober 2026. Update via “Update firmware”: elk antwoord wordt nu gecontroleerd tegen de batterij waar het vandaan komt, en model, serienummer en cycli van elke batterij corrigeren zichzelf binnen enkele minuten. Blijft er na de update iets niet kloppen, antwoord dan gerust op deze e-mail.