🍂 Autumn offer — Pylon-Monitor V2 €59 €49 · -17% off · Ends September 30 →
Designed & made in France
Answered Compatibility Generation 2 & Lite

Does Pylon-Monitor work with an SC0500 controller and 7 × H48050 behind it?

Asked · Updated · 1 answer

Short answer

Yes, since firmware 2.8 (generation 2 and Lite): H48050 modules behind an SC0500 controller are read through the controller's Console port, with nothing to configure — state of charge, voltage, current, temperatures, every module and every cell, alarms and status.

Customer V. Question

Hello, does the monitor work with an SC0500 controller? There are 7 H48050 behind it. Thank you in advance.

Pylon-Monitor teamOfficial answer

Yes: since firmware 2.8, Pylon-Monitor reads H48050 modules behind an SC0500 controller, through its Console port. It detects the high-voltage pack by itself, with nothing to configure. You get state of charge, voltage, current, temperatures, every module and every cell, alarms and status.

To be fully transparent: this high-voltage support was built from real console readings of Pylontech controllers, but we have not yet had a high-voltage pack connected to a Pylon-Monitor in our workshop. If your controller answers differently, the device has a diagnostic page that collects its replies, and we would adapt the firmware.

Was this answer helpful?
#SC0500#H48050#high voltage#HV#Force H

Published without names or contact details. Customers are shown by initial and country only.